Standard drawings addendums

View our standard drawing addendums.

Standard drawing numberAddendums to standard drawings for use in Sunshine Coast Council
GS-041, 44 & 45Black posts/Black weld mesh or as specified council
GS-042Bollard detail excepted only - no log fence. General use material preference is recycled plastic.Where bollards are located adjacent to kerbside parking they should be a minimum of 800mm back from the face of kerb.Bollards should provide colour and luminance contrast to their surroundings, particularly if they are adjacent to a pathway or disabled parking bays
TMR 1603Black only PVC not green plastic, posts to be painted black
GS-011Use SM3 kerb type and concrete backing strip of 200mm instead of the B6
DRAINAGE

Inlet capacity charts are available on request without prejudice.  Designers need to allow for local conditions. Maximum depth of pit is 1.8m
DS-030Lean mix concrete is not allowed within the pavement box
DS-041Straw bales not used
DS-061Use of VS (1200mm) lintel is acceptable
ROADS
RS-065Pathway widths- Access Street - 2.0m – minimum 1.5m around constrained point- Neighbourhood - 2.0m - minimum 1.8m around constrained point- District Collector - 3.0m - minimum 2.0m around constrained point- Sub Arterial - 3.0m - minimum 2.5m around constrained point- Arterial - minimum 3.0m - desirable 4.0m- Cycleway Local 2.5m- Cycleway Trunk 3.0m CCS Black 21 (6% pigment) coloured trunk pathway 2.5m or greater
RS-080Kerb and Channel profiles to be used in this Council are as follows:- B1 – Design speed greater than 50km/h, channel invert width is 450mm – Main Streets, Park frontages- B2 – where no stormwater flow- SM3 – Median kerb- M1 – Design speed up to and including 50km/h- ER2 – Edge restraint- INVERT – Stormwater drain inverts All kerbs shall be constructed with plain concrete using slip form with structural mix. All kerbs shall be placed on a minimum 75mm thick gravel base that extends 150mm beyond the back of kerb
RS-090Desirable kerb ramp grade is 1 in 15, achieve a best fit to a maximum of 1 in 8
RS-091Council only accepts cut-through treatments, width dimension x be a minimum of 2m. Median paths to be plain concrete with black TGSI’s
RS-0130No Council logo
RS-0131Sign posts are to be installed using a spike foundation system. Sign posts in concrete are to be installed using V-Sockets or Lock-Sockets
RS-182 & 183Bus bay concrete to be coloured 'CCS Stallion' to provide contrast to the boarding area
PARKS
PS-010Type 1 – Alternative treatment only
PS-016Rest rail accepted – no deflections rails

Current as at 9 Dec 2021